<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IECEx - Data Logger Italia</title>
	<atom:link href="https://www.data-logger.it/tag-prodotto/iecex-en/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Il tuo partner per la fornitura di strumentazione</description>
	<lastBuildDate>Wed, 11 Jul 2018 11:17:07 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.data-logger.it/wp-content/uploads/2025/10/cropped-Logo-aziendale-DATA-LOGGER-32x32.png</url>
	<title>IECEx - Data Logger Italia</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AT2-DM2000/2100 &#8211; Explosion-proof ATEX/IECEx low differential pressure transmitter</title>
		<link>https://www.data-logger.it/prodotto/at2-dm2000_2100/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Wed, 11 Jul 2018 10:11:38 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/?post_type=product&#038;p=7200</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png">      <img class="alignnone size-full wp-image-6224" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png" alt="logo_comhas" width="120" height="55" /></a></p>
<p>• Optional 3.5 digit LCD shows process and engineering units<br />
• A single bush button allows field selection of 4 to 6 engineering units depending on range</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-dm2000_2100/">AT2-DM2000/2100 &#8211; Explosion-proof ATEX/IECEx low differential pressure transmitter</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Atex:<br />
</strong>CE 1370<br />
Ex II 2G Ex d IIC T6 Gb<br />
II 2D Ex tb IIIC T85°C Db, -60°C≤T amb≤+60°C<br />
Certificate: BVI 14 ATEX 0072</p>
<p><strong>IECEx:</strong><br />
Ex d IIC T6 Gb<br />
Ex tb IIIC T85°C Db<br />
Certificate: IECEx EPS 14.0082</p>
<p><strong>Esecuzione:</strong><br />
IP66 (IP65 with option OPV)</p>
<p><strong>SPECIFICATIONS</strong></p>
<p>Service: air and non-combustible, compatible gases<br />
Wetted materials: consult factory<br />
<strong>Accuracy:</strong> ­ ±1% f.s. at 70°F<br />
<strong>Stability:</strong> 1% f.s. year<br />
<strong>Temperature limits:</strong><br />
Transmitter: 20 to 120°F (-6.67 to 48.9°C)<br />
Case: -76 to 140°F (-60 to 60°C)*<br />
<strong>Pressure limits:</strong> 10 psig (0.69 bar).<br />
<strong>Thermal effect:</strong> ±0.055% f.s.°F (0.099% f.s.°C).<br />
<strong>Response time:</strong> Additional delay in response time due to flame arrestors,<br />
from full scale to 0 up to 90 sec depending on model range<br />
<strong>Power requirements:</strong> 10-35 VDC (2 wire)<br />
<strong>Output signal:</strong> 4 to 20 mA<br />
<strong>Zero and span adjustments:</strong> Digital push-button zero and span<br />
<strong>Loop cesistance:</strong> DC: 0-1250 ohms maximum<br />
<strong>Current consumption:</strong> DC: 38 mA maximum<br />
<strong>Electrical connections:</strong> Screw-type terminal block<br />
<strong>Display:</strong> 3.5 digit LCD, 0.7” height<br />
<strong>Mounting orientation:</strong> Vertical</p>
<p><strong>HOUSING</strong></p>
<p><strong>Housing material:</strong> alluminium (stainless steel optional)<br />
<strong>Finishing:</strong> texture epoxy coat RAL7038 suitable for installation in harsh environments.<br />
<strong>Process connections: 1</strong>/8” female NPT brass (stainless steel optional)<br />
<strong>Electrical connection:</strong> ¾” NPT F (cable gland non included)<br />
<strong>Dimensions:</strong> see drawing below<br />
<strong>Weight:</strong> ab. 5 kg</p>
<p><em>* Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p><em>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES! </em><br />
<em>CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</em></p>
<p>&nbsp;</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-dm2000_2100/">AT2-DM2000/2100 &#8211; Explosion-proof ATEX/IECEx low differential pressure transmitter</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AT2-MS &#8211; ATEX/IECEx Exd Magnesense® low differential pressure transmitter</title>
		<link>https://www.data-logger.it/prodotto/at2-ms-atex-iecex%e2%80%88exd-magnesense-low-differential-pressure-transmitter/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Mon, 27 Jul 2015 13:27:45 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/prodotto/at2-ms-atex-iecex%e2%80%88exd-magnesense-low-differential-pressure-transmitter/</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" />      </a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png"><img class="alignnone size-full wp-image-6224" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png" alt="logo_comhas" width="120" height="55" /></a></p>
<p>• AT2-MS differential pressure transmitters in Exd Atex/IECEx enclosures<br />
• Ranges from 0-0.1 inch W.C. (0-25 Pa) to 25 inch W.C. (5 KPa)<br />
• Zero center ranges<br />
• Monitors pressure &#38; air velocity<br />
• Display LCD optional</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-ms-atex-iecex%e2%80%88exd-magnesense-low-differential-pressure-transmitter/">AT2-MS &#8211; ATEX/IECEx Exd Magnesense® low differential pressure transmitter</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>AT2-MS specifications</strong></p>
<p><strong>Service:</strong> air and compatible gases and dry gases.<br />
<strong>Wetted parts:</strong> consult factory.<br />
<strong>Temperature limits:</strong> Magnesense®: from 0 to 150°F (-18 to 66°C).<br />
<strong>Case:</strong> from -60 to 60°C*.<br />
<strong>Pressure limits:</strong> 1 psi max. operative pressure. 10 psi burst.<br />
<strong>Accuracy:</strong> ±1% f.s. for ranges: 0.25”, 0.5”, 2”, 5”, 10”, 15”, 25”, 50 Pa, 100 Pa, 500 Pa, 1250 Pa, 2 KPa, 3 KPa, 5 KPa. ±2% for ranges: 0.1”-1”, 25 Pa, 250 Pa and all bi-directional ranges<br />
<strong>Stability:</strong> ±1% f.s. / year.<br />
<strong>Power requirements:</strong> 10 to 35 VDC (2-wire); 17 to 36 VDC or isolated 21.6 to 33 VAC (3-wire).<br />
<strong>Output signals:</strong> 4 to 20 mA (2-wire); 0 to 5 V, 0 to 10 V (3-wire).<br />
<strong>Response time:</strong> field adjustable 0.5 to 15 sec. time constant. Provides a 95% response time of 1.5 to 45 seconds (additional delay in response time due to flame arrestors; from full scale to ø up to 90 sec depending on model range).<br />
<strong>Zero &amp; span adjustments:</strong> Digital push button (to be made in safe area).<br />
<strong>Loop resistance:</strong> Current output: 0-1250 Ohm max.<br />
<strong>Voltage Output: </strong>min. load resistance 1 kOhm.<br />
<strong>Current consumption:</strong> 40 mA max..<br />
<strong>Display (optional):</strong> 4 digit LCD.<br />
<strong>Electrical connections:</strong><br />
4-20 mA, 2-wire: European Style terminal block for 16 to 26 AWG.<br />
0-10 V, 3-wire: European Style terminal block 16 to 22 AWG.<br />
<strong>Housing material:</strong> aluminium (stainless steel optional).<br />
<strong>Finishing:</strong> texture epoxy coat RAL7038 (only aluminium enclosure).<br />
<strong>Pressure connections:</strong> 1/8” NPT F brass (stainless steel optional). In presence of acetylene it is necessary to use stainless steel.<br />
<strong>Electrical connections:</strong> 2 x 1/2” NPT F standard (cable gland not included).<br />
<strong>Dimensions:</strong> see drawing below<br />
<strong>Weight:</strong> 5 Kg ab. (blind)</p>
<p><em>* Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p><strong>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES! </strong><br />
<strong>CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</strong></p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-ms-atex-iecex%e2%80%88exd-magnesense-low-differential-pressure-transmitter/">AT2-MS &#8211; ATEX/IECEx Exd Magnesense® low differential pressure transmitter</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AT2-3000MR/MRS &#8211; Explosion-proof ATEX/IECEx Exd Photohelic® pressure switch/gages</title>
		<link>https://www.data-logger.it/prodotto/at2-3000mr-mrs/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Wed, 11 Jul 2018 10:38:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/?post_type=product&#038;p=7211</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" /></a></p>
<p>• Atex/IECEX Exd Photohelic® pressure switch/gage now available from Comhas as single instrument Atex approuved<br />
• 3 in 1, indicating gage, lo-limit and hi-limit control<br />
• Repeatability ±2%</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-3000mr-mrs/">AT2-3000MR/MRS &#8211; Explosion-proof ATEX/IECEx Exd Photohelic® pressure switch/gages</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Atex:<br />
</strong>CE <strong>1</strong>370<br />
Ex II 2G Ex d IIC T6 Gb<br />
II 2D Ex tb IIIC T85°C Db, -60°C≤T amb≤+60°C<br />
Certificate: BVI 14 ATEX 0072</p>
<p><strong>IECEx:</strong><br />
Ex d IIC T6 Gb<br />
Ex tb IIIC T85°C Db<br />
Certificate: IECEx EPS 14.0082</p>
<p><strong>Esecuzione:</strong><br />
IP66 (IP65 with option OPV)</p>
<p>Photohelic® switch/gages series AT3-A3000 function as versatile, highly repeatable pressure switches combined with a precise pressure gage employing the time-proven Magnehelic® gage design. The Photohelic® switch/gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure also available. Two phototransistor actuated, DPDT relays are included for low/high limit control. easy to adjust setpoint indicators are controlled by knobs located on the gage face (accessible opening case after de-enegizing instrument).<br />
Individual setpoint deadband is one pointer width &#8211; less than 1% of full scale. Setpoints can be interlocked to provide variable deadband &#8211; ideal for control of fans, dampers, etc. Gage reading is continuous and unaffected by switch operation, even during loss of electrical power.<br />
Several ranges available (see standard ranges table).</p>
<p><strong>AT2-3000MR/MRS specifications</strong></p>
<p><strong>Service:</strong> air and compatible clean and dry gases.<br />
<strong>Wetted parts:</strong> consult factory.<br />
<strong>Temperature limits*:</strong><br />
Photohelic®: from -6.67 a 48.9°C (20 to 120°F). Option “LT” low temperature to -20°F (-28.8°C) see also case temperature limits.<br />
Case: from -60 to 60°C (see also above, Photohelic® temperature limits).<br />
<strong>Accuracy:</strong> ±2% f.s. at 70°F (21.1°C); ±3% on -0; ±4% on -00 models<br />
<strong>Pressure limits:</strong> -20” Hg to 25 psig (-0.677 bar to 1.72 bar).<br />
MP option; 35 psig (2.41 bar)<br />
HP option; 80 psig (5.52 bar).<br />
A36003S – A36010S; 150 psig (10.34 bar).<br />
<strong>Dial size:</strong> 4” (101.6 mm).<br />
<strong>Mounting orientation: </strong>diaphragm in vertical position.<br />
<strong>Housing material:</strong> alluminium (optional stainless steel).<br />
<strong>Finishing:</strong> texture epoxy coat RAL7038 (only aluminium housings).<br />
<strong>Process connections:</strong> 1/8” female NPT brass (stainless steel optional).<br />
In case of acetylene presence it is compulsory to use stainless steel.<br />
<strong>Electrical wiring:</strong> screw terminals.<br />
<strong>Electrical connection:</strong> 3 x 1/2” NPT F standard (supplied without cable gland).<br />
<strong>Set point adjustment:</strong> adjustable knobs on face of Photohelic® available behind cover<br />
(follow instructions and ­safety warnings to open cover).<br />
<strong>Dimensions:</strong> see drawing below.<br />
<strong>Weight:</strong> 12,9 Kg ab.<br />
<strong>Response time**:</strong> from f.s. to 0 up to 120 sec. max<br />
(mainly for low ranges models 60, 100 e 125 Pa or equivalentes).</p>
<p><strong>SWITCH SPECIFICATIONS</strong></p>
<p><strong>Switch Type:</strong> each setpoint has 1 form C relay (SPDT).<br />
<strong>Repeatability:</strong> ±1% of full scale.<br />
<strong>Electrical rating:</strong> 10A @ 28 Vcc; 10A @ 120, 240 Vca.<br />
<strong>Power requirements:</strong> 120 VAC, 50/60 Hz;</p>
<p><em>* The operating ambient temperature it is always defined by the limits of measuring elements or options selected.</em><br />
<em>** For applications with high cycle rate within gage total pressure rating, next higher rating is recommended. See medium and high options.</em></p>
<p><strong>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES! </strong><br />
<strong>CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</strong></p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-3000mr-mrs/">AT2-3000MR/MRS &#8211; Explosion-proof ATEX/IECEx Exd Photohelic® pressure switch/gages</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AT2-DH3 &#8211; Explosion-Proof ATEX/IECEx Exd Digihelic® differential pressure controller</title>
		<link>https://www.data-logger.it/prodotto/at2-dh3at2-dh3_explosion-proof_atex-iecex%e2%80%88exd-digihelic-differential-pressure-controller/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Mon, 27 Jul 2015 12:59:52 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/prodotto/at2-dh3at2-dh3_explosion-proof_atex-iecex%e2%80%88exd-digihelic-differential-pressure-controller/</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" /></a></p>
<p>• DH3 transmitter/controller now available from Comhas as single instrument Atex/IECEX approuved<br />
• 3 in 1, digital display gage, control relay switches and transmitter<br />
• Ideal instrument for pressure, velocity and flow applications</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-dh3at2-dh3_explosion-proof_atex-iecex%e2%80%88exd-digihelic-differential-pressure-controller/">AT2-DH3 &#8211; Explosion-Proof ATEX/IECEx Exd Digihelic® differential pressure controller</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>AT2-607D specifications</strong></p>
<p><strong>Service:</strong> air ir and compatible clean and dry gases.<br />
<strong>Wetted parts:</strong> consult factory.<br />
<strong>DH3 case:</strong> die cast aluminum case and bezel.<br />
<strong>Temperature limits:</strong> DH3®: from 0 to 60°C (32 to 140°F).<br />
<strong>Case:</strong> from -60 to 60°C* (-76 to 140°F).<br />
<strong>Accuracy:</strong> &lt;5” w.c. (except ±2.5” w.c.): ±1%;<br />
<strong>All other ranges:</strong> ±0.5% at 77°F (25°C) including hysteresis and repeatability (after 1 hour warm-up).<br />
<strong>Stability:</strong> &lt;±1% per year.<br />
<strong>Pressure limits:</strong><br />
Range ≤ 622.7 Pa (2.5” w.c.) P-max: 172 KPa (25 psi);<br />
Range ±622.7 Pa (±2.5”) and 1245 Pa (5” w.c) P-max: 34.4 KPa (5 psi);<br />
Range 6227 Pa (25” w.c) and 12.45 KPa (50” w.c.) P-max: 34.4 KPa (5 psi);<br />
Range 24.91 KPa (100” w.c) P-max: 62 KPa (9 psi).<br />
<strong>Compensated temperature limits:</strong> from 0 a 60°C (32 to 140°F).<br />
<strong>Thermal effects:</strong> 0.036/°C, from 25°C (0,020% of from 77°F).<br />
<strong>Power requirements:</strong> 12-28 Vdc, 12-28 Vac 50-400 Hz.<br />
<strong>Power consumption:</strong> 3 VA max.<br />
<strong>Output signal:</strong> 4-20 mA, max 900 ohm.<br />
<strong>Zero &amp; span adjustments:</strong> accessible via menus (possible only in safe area).<br />
<strong>Response time:</strong> 250 ms (damping set to 1). Without considering delay caused by Exd flame arrestors<br />
(up to 90 sec. from full scale to zero depending model and range).<br />
<strong>Display:</strong> backlit 4 digit LCD 0.4” height LED indicators for set point and alarm status.<br />
<strong>Installation:</strong> diaphragm in vertical position.<br />
Dial size: 5” (127 mm).<br />
<strong>Housing material:</strong> alluminium (stainless steel option).<br />
<strong>Finishing:</strong> texture epoxy coat RAL7038 (only aluminium enclosure).<br />
<strong>Electrical wiring:</strong> screw terminal.<br />
<strong>Electrical connection:</strong> 2 x 1/2” NPT F standard (supplied without cable galnd).<br />
<strong>Process connections:</strong> 1/8” female NPT brass (stainless steel optional).<br />
In case of acetylene presence it is requested to use stainless steel.<br />
<strong>Dimensions:</strong> see drawing below.<br />
<strong>Weight:</strong> 5.6 Kg ab.</p>
<p><strong>SWITCH SPECIFICATIONS</strong></p>
<p><strong>Switch type:</strong> 2 Relè SPDT.<br />
<strong>Rating relay:</strong> 1A @ 30 Vac/Vdc.<br />
<strong>Set point adjustment:</strong> adjustable via keypad on face (possible only in safe zone).<br />
<em>* Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p><strong>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES! </strong><br />
<strong>CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</strong></p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-dh3at2-dh3_explosion-proof_atex-iecex%e2%80%88exd-digihelic-differential-pressure-controller/">AT2-DH3 &#8211; Explosion-Proof ATEX/IECEx Exd Digihelic® differential pressure controller</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AT2-605 &#8211; Differential pressure transmitter 605 for low ranges atex/iecex Exd</title>
		<link>https://www.data-logger.it/prodotto/at2-605/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Mon, 27 Jul 2015 12:43:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/prodotto/at2-605/</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" /></a>       <a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png"><img class="alignnone size-full wp-image-6224" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png" alt="logo_comhas" width="120" height="55" /></a></p>
<p>• Dwyer® 605 gage/transmitter now available from Comhas as single instrument Atex/IECEX approuved<br />
• Local indicator of differential pressure<br />
• Output 4-20 mA – 2 wire</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-605/">AT2-605 &#8211; Differential pressure transmitter 605 for low ranges atex/iecex Exd</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Atex:<br />
</strong>II 2G Ex d IIC T6 Gb<br />
II 2D Ex tb IIIC T85°C Db, -60°C≤Tamb≤+60°C</p>
<p><strong>IECEx:</strong><br />
Ex d IIC T6 Gb<br />
Ex tb IIIC T85°C Db<br />
Certificato: IECEx EPS 14.0082</p>
<p><strong>Esecuzione:</strong><br />
IP66 (IP65 with option OPV)</p>
<p><strong>Specifications</strong></p>
<p><strong>Service:</strong> air and compatible clean and dry gases<br />
<strong>Wetted parts:</strong> consult factory<br />
<strong>Accuracy:</strong> see “standard table ranges”<br />
<strong>Pressure limits:</strong> see “standard table ranges”.<br />
<strong>Temperature limits:</strong><br />
605 transmitter: from 20 to 120°F (-6.67 to 48.9°C)<br />
Case: from -76 to 140°F (-60 to 60°C)*<br />
<strong>Dial size:</strong> 4” (101.6 mm).<br />
<strong>Mounting orientation:</strong> Diaphragm in vertical position<br />
<strong>Housing material</strong>: alluminium (optional stainless steel).<br />
<strong>Finishing:</strong> texture epoxy coat RAL7038 (only aluminium enclosure).<br />
<strong>Process connections:</strong> 1/8” female NPT brass (stainless steel optional). In case of acetylene presence it is requested to use stainless steel.<br />
<strong>Electrical wiring:</strong> screw terminals.<br />
<strong>Electrical connection:</strong> 2 x 1/2” NPT F standard (supplied without cable gland).<br />
<strong>Dimensions:</strong> see drawing below.<br />
<strong>Weight:</strong> 5,7 Kg ab.</p>
<p><strong>TRASMITTER specifications</strong></p>
<p><strong>Compensated temperature range:</strong> from 32 to 120°F (0 a 48.9°C).<br />
<strong>Thermal effect:</strong> 0.045% f.s./°C.<br />
<strong>Power requirements:</strong> 10-35 Vdc (2-wires).<br />
<strong>Output signal:</strong> 4-20 mA.<br />
<strong>Zero and span adjustment:</strong> protected potentiometer on 605 face<br />
(can access those opening case allowed only in safe zone).<br />
<strong>Loop resistance:</strong> DC; 0-1250 ohms max.<br />
<strong>Current consumption:</strong> DC; 38 mA max.<br />
Electrical connection: screw terminal block.</p>
<p><em>* Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p><strong>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES! </strong><br />
<strong>CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</strong></p>
<p>&nbsp;</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-605/">AT2-605 &#8211; Differential pressure transmitter 605 for low ranges atex/iecex Exd</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AT1-ADPS &#038; EDPS &#8211; Differential pressure switch for low ranges ATEX/IECEx Exd approuved</title>
		<link>https://www.data-logger.it/prodotto/at1-adps-edps-differential-pressure-switch%e2%80%88for%e2%80%88low%e2%80%88ranges-atexiecex%e2%80%88exd-approuved/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Fri, 24 Jul 2015 13:42:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/prodotto/at1-adps-edps-differential-pressure-switch%e2%80%88for%e2%80%88low%e2%80%88ranges-atexiecex%e2%80%88exd-approuved/</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" /></a>     <a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png"><img class="alignnone size-full wp-image-6224" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png" alt="logo_comhas" width="120" height="55" /></a><br />
• ADPS &#38; EDPS differential pressure switch now available from Comhas as single<br />
instrument Atex/IECEx approuved<br />
• Ranges from 20 to 4000 Pa</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at1-adps-edps-differential-pressure-switch%e2%80%88for%e2%80%88low%e2%80%88ranges-atexiecex%e2%80%88exd-approuved/">AT1-ADPS &#038; EDPS &#8211; Differential pressure switch for low ranges ATEX/IECEx Exd approuved</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Atex:<br />
</strong>II 2G Ex d IIC T6 Gb<br />
II 2D Ex tb IIIC T85°C Db, -60°C≤Tamb≤+60°C</p>
<p><strong>IECEx:</strong><br />
Ex d IIC T6 Gb<br />
Ex tb IIIC T85°C Db<br />
Certificato: IECEx EPS 14.0082</p>
<p><strong>Esecuzione:</strong><br />
IP66 (IP65 with option OPV)</p>
<p><strong>CARATTERISTICHE TECNICHE</strong></p>
<ol>
<li><strong>Service:</strong> air and compatible gases and dry gases.</li>
<li><strong>Wetted materials:</strong><br />
ADPS: Diaphragm material: Silicone<br />
Housing material: POM<br />
Switch body: PA 6.6<br />
Cover: Polystyrene</li>
<li><strong>Wetted materials EDPS:</strong><br />
• Diaphragm material: Silicone<br />
• Housing material: switch body PA 6.6<br />
• Cover: Polystyrene<br />
• Materials UL94 V-0 rated</li>
<li><strong>Temperature limits:</strong><br />
• Pressure switch ADPS/EDPS: from -20 to 85°C<br />
• Case: -76 to 140°F (-60 to 60°C)*</li>
<li><strong>Pressure limits:</strong> max operating pressure 10 kPa.</li>
<li><strong>Switch:</strong> type SPDT.</li>
<li><strong>Electrical rating:</strong> max. frequency 6 cycles/min.</li>
<li><strong>Electrical wiring:</strong> 3 screw type, common, normally open and normally closed.</li>
<li><strong>Set point adjustement:</strong> hand knob on pressure switch ADPS inside case (de-energise before opening case).</li>
<li><strong>Installation:</strong> diaphragm in vertical position.</li>
<li><strong>Housing material:</strong> aluminium (stainless steel optional).</li>
<li><strong>Finishing:</strong> texture epoxy coat RAL7038 (only aluminium case).</li>
<li><strong>Pressure connections:</strong> 1/8” NPT F brass (stainless steel optional). In presence of acetylene it is necessary to use stainless steel.</li>
<li><strong>Electrical connections:</strong> 2 x 1/2” NPT F standard (cable gland not included).</li>
<li><strong>Dimensions:</strong>     see drawing below</li>
<li><strong>Weight: </strong>3,2 Kg ab. (blind).</li>
</ol>
<p><strong>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES!<br />
CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN..</strong></p>
<p><strong>Important notes for installation:</strong><br />
• Cables must be fitted through 1/2” NPT cable gland or Atex/IECEx conduit (not supplied withinstrument).<br />
• Make sure after cabling to close tight cover and cable gland, in order to keep IP66 rating (IP65 with option OPV, pressure reliev valve).<br />
• Open cover only after de-energising instrument.<br />
• Attention: check local safety rules and warnings on unit and manual for a correct use of the instrument in hazardous area.<strong><br />
</strong></p>
<p><em>*Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at1-adps-edps-differential-pressure-switch%e2%80%88for%e2%80%88low%e2%80%88ranges-atexiecex%e2%80%88exd-approuved/">AT1-ADPS &#038; EDPS &#8211; Differential pressure switch for low ranges ATEX/IECEx Exd approuved</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title></title>
		<link>https://www.data-logger.it/prodotto/7225/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Fri, 24 Jul 2015 14:23:13 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/prodotto/7225/</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" />        </a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png"><img class="alignnone size-full wp-image-6224" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png" alt="logo_comhas" width="120" height="55" /></a></p>
<p>• 1800 differential pressure switch now available from Comhas as single instrument Atex/IECEX approuved<br />
• 9 models for set points from 18 Pa to 21.6 KPa<br />
• Repeatability ±2%</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/7225/"></a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Atex:<br />
</strong>II 2G Ex d IIC T6 Gb<br />
II 2D Ex tb IIIC T85°C Db, -60°C≤Tamb≤+60°C</p>
<p><strong>IECEx:</strong><br />
Ex d IIC T6 Gb<br />
Ex tb IIIC T85°C Db<br />
Certificato: IECEx EPS 14.0082</p>
<p><strong>Esecuzione:</strong><br />
IP66 (IP65 with option OPV)</p>
<p><strong>AT2-607D specifications</strong></p>
<p><strong>Service:</strong> air and compatible clean and dry gases.<br />
<strong>Wetted parts:</strong> consult factory (sylicon rubber diaphragm)<br />
<strong>Temperature limits*:</strong> Pressure switch 1800: from -34 to 82.2°C (-30 to 180°F)<br />
from -28.9 to 82.2°C (-20 to 180°F) &#8211; mod.1823-00<br />
<strong>Case:</strong> from -60 to 60°C*<br />
<strong>Pressure limits:</strong> 68.95 kPa continuous (10 Psig); 172.4 kPa surge (25 Psig)<br />
<strong>Switch:</strong> SPDT type<br />
<strong>Ripeatability:</strong> ±2%.<br />
<strong>Electrical rating:</strong> 15A @ 120-480 Vac, 60 Hz, Resistive 1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac, 60 Hz.<br />
Derate to 10 A for operation at high cycles rates.<br />
<strong>Electrical wiring:</strong> 3 screw type, common, normally open and normally closed.<br />
<strong>Set point adjustement:</strong> internal or with external knob (optional).<br />
<strong>Mounting orientation:</strong> diaphragm in vertical position.<br />
<strong>Housing material:</strong> alluminium (optional stainless steel).<br />
<strong>Finishing:</strong> texture epoxy coat RAL7038 (only aluminium case)<br />
<strong>Process connections:</strong> 1/8” female NPT brass (stainless steel optional). In case of acetylene presence it is request to use stainless steel.<br />
<strong>Electrical connection:</strong> 2 x 1/2” NPT F standard (supplied without cable gland).<br />
Dimensions: see drawing below.<br />
<strong>Weight:</strong> 5.4 Kg ab.</p>
<p><em>* Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES!<br />
CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/7225/"></a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AT2-607 &#8211; Explosion-Proof ATEX/IECEx Exd low differential pressure transmitter</title>
		<link>https://www.data-logger.it/prodotto/at2-607-explosion-proof-atex-iecex%e2%80%88exd-low-differential-pressure-transmitter/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Wed, 11 Jul 2018 11:11:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/?post_type=product&#038;p=7236</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" />        </a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png"><img class="alignnone size-full wp-image-6224" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png" alt="logo_comhas" width="120" height="55" /></a></p>
<p>• Very low range with exceptional stability<br />
• Either ±0.25% or ±0.5% f.s.<br />
• Ultra thin glass clad silicon diaphragm design resists shock and vibration, practically eliminate drift</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-607-explosion-proof-atex-iecex%e2%80%88exd-low-differential-pressure-transmitter/">AT2-607 &#8211; Explosion-Proof ATEX/IECEx Exd low differential pressure transmitter</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Atex:<br />
</strong>CE 1370<br />
Ex II 2G Ex d IIC T6 Gb<br />
II 2D Ex tb IIIC T85°C Db, -60°C≤T amb≤+60°C<br />
Certificate: BVI 14 ATEX 0072</p>
<p><strong>IECEx:</strong><br />
Ex d IIC T6 Gb<br />
Ex tb IIIC T85°C Db<br />
Certificate: IECEx EPS 14.0082</p>
<p><strong>Esecuzione:</strong><br />
IP66 (IP65 with option OPV)</p>
<p><strong>AT2-607 specifications</strong></p>
<p><strong>Service:</strong> air and nonconductive<br />
<strong>Wetted materials:</strong> consult factory<br />
<strong>Accuracy:</strong> ±0.5% or ±0.25% f.s.<br />
<strong>Stability:</strong> ±0.5% f.s.o. year<br />
<strong>Temperature limits:</strong><br />
transmitter: -20 to 160°F (-29 to 71°C), 10 to 95% RH<br />
case: -76 to 140°F (-60 to 60°C)*<br />
<strong>Pressure limits:</strong> 10 psig (0.69 bar)<br />
<strong>Compensated temperature range:</strong> 35 to 135°F (2 to 57°C)<br />
<strong>Thermal effects:</strong> ±0.015% f.s.°F (zero and span)<br />
<strong>Power requirements:</strong> 12-36 VDC<br />
<strong>Output signal:</strong> 4 to 20 mA DC, 2-wire<br />
<strong>Zero and span adjustments:</strong> externally accessible potentiometers, non-interactive, ±10% f.s. adjustment (only in safe area)<br />
<strong>Response time:</strong> 250 msec max (additional delay in response time due to flame arrestors;<br />
from full scale to 0 up to 90 sec depending on model range)<br />
<strong>Loop resistance:</strong><br />
0 to 1045 ohms<br />
Vmin=12V+[(.22A)(RL)]<br />
<strong>Current consumption:</strong> 3.6 mA (min)<br />
<strong>Electrical connections:</strong> screw terminals</p>
<p><strong>HOUSING</strong></p>
<p><strong>Material:</strong> alluminium (stainless steel optional)<br />
<strong>Finishing:</strong> texture epoxy coat RAL7038 suitable for installation in harsh environments.<br />
<strong>Process connections:</strong> 1/8” Female NPT brass (stainless steel optional)<br />
<strong>Electrical connection:</strong> 1/2” NPT F (cable gland non included)<br />
<strong>Dimensions:</strong> see drawing below</p>
<p><em>* Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p><strong>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES! </strong><br />
<strong>CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</strong></p>
<p>&nbsp;</p>
<p><strong>Important notes for installation:<br />
</strong>Cables must be fitted through 1/2” NPT cable gland or Atex/IECEX conduit (not supplied with instrument).<br />
Make sure after cabling to close tight cover and cable gland, in order to keep IP66 rating<br />
(IP65 with option OPV, pressure reliev valve).<br />
Open cover only after de-energising instrument.<br />
Attention: check local safety rules and warnings on unit and manual for a correct use</p>
<p>&nbsp;</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-607-explosion-proof-atex-iecex%e2%80%88exd-low-differential-pressure-transmitter/">AT2-607 &#8211; Explosion-Proof ATEX/IECEx Exd low differential pressure transmitter</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AT2-607D &#8211; Explosion-Proof ATEX/IECEx Exd low differential pressure transmitter</title>
		<link>https://www.data-logger.it/prodotto/at2-607d-explosion-proof-atex-iecex%e2%80%88exd-low-differential-pressure-transmitter/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Wed, 11 Jul 2018 11:03:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/?post_type=product&#038;p=7229</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" />        </a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png"><img class="alignnone size-full wp-image-6224" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png" alt="logo_comhas" width="120" height="55" /></a></p>
<p>• Accuracy: ±0.25% f.s.<br />
• Ranges from 0.1 to 25 in w.c.</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-607d-explosion-proof-atex-iecex%e2%80%88exd-low-differential-pressure-transmitter/">AT2-607D &#8211; Explosion-Proof ATEX/IECEx Exd low differential pressure transmitter</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Atex:<br />
</strong>CE 1370<br />
Ex II 2G Ex d IIC T6 Gb<br />
II 2D Ex tb IIIC T85°C Db, -60°C≤T amb≤+60°C<br />
Certificate: BVI 14 ATEX 0072</p>
<p><strong>IECEx:</strong><br />
Ex d IIC T6 Gb<br />
Ex tb IIIC T85°C Db<br />
Certificate: IECEx EPS 14.0082</p>
<p><strong>Esecuzione:</strong><br />
IP66 (IP65 with option OPV)</p>
<p><strong>AT2-607D specifications</strong></p>
<p><strong>Service:</strong> air and non-conductive, noncorrosive gases.<br />
<strong>Wetted materials:</strong> 302 SS, glass, nickel, silicone rubber and brass.<br />
<strong>Accuracy:</strong> ±0.25% f.s.* at room temperature *RSS includes nonlinearity, hysteresis and nonrepeatibility.<br />
<strong>Stability:</strong> ±1% f.s. year<br />
<strong>Temperature limits:</strong><br />
operating and compensated: 0 to 170°F (-18 to 77°C)<br />
storage: -65 to 185°F (-54 to 85°C)<br />
case: -76 to 140°F (-60 to 60°C)*<br />
<strong>Pressure limits:</strong> 15 psi (100 kPa)<br />
<strong>Power requirements:</strong> 16 to 32 VDC<br />
<strong>Output signal:</strong> 4 to 20 mA<br />
<strong>Zero adjustment:</strong> potentiometer for zero<br />
<strong>Max loop resistance:</strong> DC 0 to 800 Ohms<br />
<strong>Electrical connections:</strong> screw-type terminal block.<br />
<strong>Mounting orientation:</strong> vertical, on a 1.378” (35 mm) DIN rail.<br />
<strong>Thermal effects:</strong> includes zero and span ±0.01 f.s.°F, 20 to 170°F (-7 to 77°C)<br />
<strong>Response time:</strong> approximately 10 ms. Additional delay in response time due to flame arrestors; from full scale to 0 up to 90 sec depending on model range.</p>
<p><strong>HOUSING</strong></p>
<p><strong>Material:</strong> alluminium (stainless steel optional)<br />
<strong>Finishing:</strong> texture epoxy coat RAL7038 suitable for installation in harsh environments.<br />
<strong>Process connections:</strong> 1/8” female NPT brass (stainless steel optional)<br />
<strong>Electrical connection:</strong> 1/2” NPT F (cable gland non included)<br />
<strong>Dimensions:</strong> see drawing below<br />
<strong>Weight:</strong> ab. 5 kg</p>
<p><em>* Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p><strong>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES! </strong><br />
<strong>CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</strong></p>
<p><strong>Important notes for installation:<br />
</strong>Cables must be fitted through 1/2” NPT cable gland or Atex/IECEX conduit (not supplied with instrument).<br />
Make sure after cabling to close tight cover and cable gland, in order to keep IP66 rating<br />
(IP65 with option OPV, pressure reliev valve).<br />
Open cover only after de-energising instrument.<br />
Attention: check local safety rules and warnings on unit and manual for a correct use</p>
<p>&nbsp;</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at2-607d-explosion-proof-atex-iecex%e2%80%88exd-low-differential-pressure-transmitter/">AT2-607D &#8211; Explosion-Proof ATEX/IECEx Exd low differential pressure transmitter</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AT1-1900 &#8211; Explosion-proof atex/iecex Exd differential pressure switch for low ranges</title>
		<link>https://www.data-logger.it/prodotto/at1-1900-explosion-proof-atex-iecex%e2%80%88exd-differential-pressure-switch-for-low-ranges/</link>
		
		<dc:creator><![CDATA[Flavia Zuncheddu]]></dc:creator>
		<pubDate>Fri, 24 Jul 2015 10:47:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.data-logger.it/prodotto/at1-1900-explosion-proof-atex-iecex%e2%80%88exd-differential-pressure-switch-for-low-ranges/</guid>

					<description><![CDATA[<p><a href="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg"><img class="alignnone size-full wp-image-4770" src="https://www.data-logger.it/wp-content/uploads/2014/12/ATEX_WEB_COMHAS.jpg" alt="ATEX_WEB_COMHAS" width="50" height="44" /></a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg">     <img class="alignnone size-full wp-image-5475" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_iecex.jpg" alt="logo_iecex" width="44" height="44" />       </a><a href="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png"><img class="alignnone size-full wp-image-6224" src="https://www.data-logger.it/wp-content/uploads/2015/07/logo_comhas.png" alt="logo_comhas" width="120" height="55" /></a></p>
<p>• One of the most popular Dwyer® pressure switchseries 1900 it is now available from<br />
Comhas as single instrument Atex/IECEx approuved<br />
• 6 models for operating ranges from 0.07 inches W.C. (18 Pascal) to 20 inches W.C. (5000 Pascal)<br />
• Repeatability ±3%</p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at1-1900-explosion-proof-atex-iecex%e2%80%88exd-differential-pressure-switch-for-low-ranges/">AT1-1900 &#8211; Explosion-proof atex/iecex Exd differential pressure switch for low ranges</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Atex:<br />
</strong>II 2G Ex d IIC T6 Gb<br />
II 2D Ex tb IIIC T85°C Db, -60°C≤Tamb≤+60°C</p>
<p><strong>IECEx:</strong><br />
Ex d IIC T6 Gb<br />
Ex tb IIIC T85°C Db<br />
Certificato: IECEx EPS 14.0082</p>
<p><strong>Esecuzione:</strong><br />
IP66 (IP65 with option OPV)</p>
<p><strong>AT1-1900 specifications</strong></p>
<p><strong>Service:</strong> air and compatible gases<br />
<strong>Wetted parts:</strong> consult factory<br />
<strong>Temperature limits:</strong><br />
Pressure switch 1900: -30 to 180°F (-34 to 82.2°C)<br />
Case: -76 to 140°F (-60 to 60°C)*<br />
<strong>Pressure limits:</strong> 45”W.C. (11.2 kPa) continuous; 10 psig (68.95 kPa) surge.<br />
<strong>Switch:</strong> type SPDT.<br />
<strong>Repeatability:</strong> ±3%.<br />
<strong>Electrical rating:</strong> 15A @ 120-480 VAC.<br />
60 Hz resistivo;<br />
1/8 HP @ 125 VAC;<br />
1/4 HP @ 250 VAC, 60 Hz.<br />
Derate to 10A for operating at high cycle rates.<br />
<strong>Electrical wiring:</strong> 3 screw type, common, normally open and normally closed.<br />
<strong>Set point adjustement:</strong> screw type on pressure switch inside the Exd enclosure accessibile by hole with plug on housing. Setpoint regulation must be done with instrument de energised. Follow instructions and safety warning to open cover.<br />
<strong>Installation:</strong> in vertical position.<br />
<strong>Diaphragm:</strong> silicon rubber standard.<br />
<strong>Housing material:</strong> aluminium (stainless steel optional).<br />
<strong>Finishing:</strong> texture epoxy coated L7038 (only aluminium case).<br />
<strong>Pressure connections:</strong> 1/8” NPT F brass (stainless steel optional).<br />
In presence of acetylene it is necessary to use stainless steel.<br />
<strong>Electrical connections:</strong> 2 x 1/2” NPT F standard (cable gland not included).<br />
<strong>Dimensions:</strong> see drawing below<br />
<strong>Weight:</strong> 3.4 Kg ab</p>
<p><em>* Operating ambient temperature is defined also according to the options and pressure instrument choosed.</em></p>
<p><strong>CAUTION FOR USE ONLY WITH AIR OR COMPATIBLE GASES! </strong><br />
<strong>CONTACT FACTORY FOR USE WITH GASES, OTHER THAN AIR AND NITROGEN.</strong></p>
<p>L'articolo <a href="https://www.data-logger.it/prodotto/at1-1900-explosion-proof-atex-iecex%e2%80%88exd-differential-pressure-switch-for-low-ranges/">AT1-1900 &#8211; Explosion-proof atex/iecex Exd differential pressure switch for low ranges</a> proviene da <a href="https://www.data-logger.it">Data Logger Italia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
