Atex:
CE 1370
Ex II 2 G Ex d II B + H2 T6 Gb
Ex II 2 D Ex tb IIIC Db T85
Certificate: BVI 15 ATEX 0076
IECEx:
Ex II 2 G Ex d II B + H2 T6 Gb
Ex II 2 D Ex tb IIIC Db T85
Certificate: IECEx EPS 15.0063X
Esecuzione:
IP66
SPECIFICATION
- Accuracy class: 1% f.s. – 3% f.s. for ranges over 300°C
- Dial size: 100 mm
- Sensitive element: inert gas system
- Bulb: 316 SS cylindrical diam. 11 mm (other diameters and length on request)
- Capillary: 316 SS (on request)
- Movement: 304 SS
- Pointer: black anodized aluminiumo
- Max pressure: 25 bar ( without thermowell)
- Electrical contacts:
Type MicroSwitch
Max nr 2 contacts SPDT both adjustable on entire range
Electrical rating max 3A@125 Vca / 2A@240 Vca
Internal wiring on terminal strip 2.5 mm2 cables
Contacts adjustment only from internal, opening case - Weight: ab. 2 Kg